Status

3-way manual hydraulic valve

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:3-way manual hydraulic valve.pdf
Size: 4104 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 24 May 2019, 20:21 PM
Rating: 4.6/5 from 580 votes.

Status: AVAILABLE

Last checked: 5 Minutes ago!

In order to read or download 3-way manual hydraulic valve ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

3-way manual hydraulic valveCustomer focus, innovative design, exceptional application knowledge and engineering experience are just some of the attributes which enable us to provide both standard and custom designed products to OEMs worldwide.You can find out more about which cookies we are using or switch them off in settings. Accept Privacy Overview Strictly Necessary Cookies 3rd Party Cookies Privacy Policy Powered by GDPR Cookie Compliance Privacy Overview This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful. Strictly Necessary Cookies Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.This means that every time you visit this website you will need to enable or disable cookies again. 3rd Party Cookies This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages. Keeping this cookie enabled helps us to improve our website.Privacy Policy More information about our Privacy Policy Enable All Save Changes. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. This uses a mechanical spring return and is electrically actuated.As ball valves they have zero leakage in the closed state. The directional. As ball valves they have zero leakage in the closed state. The directional. Additional characteristics. It's also featured as miniature size. C2.360 Directional control valves ND 4These electrically operated valves. FeaturesThey are available in the versions with pneumatic operation and solenoid. Application.http://alt-1c.ru/userfiles/3gmd-manual.xml

    Tags:
  • 3-way manual hydraulic valve, 4 way 3 position manual hydraulic valve, 3 way 2 position manual hydraulic valve, 3-way manual hydraulic valve, 3 way manual hydraulic valve, 3 way manual hydraulic valve, 3 way 2 position hydraulic valve manual.

The NRV valves. This valve is also ideal for service and troubleshooting of pallets used with the Hytec Automatic Pallet Coupling System. Use this valve to clamp and unclamp your fixtures off the machine. Features:Eaton DG valves. They are available in both 3 way and 4 way styles. All versions are available in 2. In particular Preo has developed a new solenoid valve that is one of the best available on the market. This valve. When using as a 3 - way valve for single-acting cylinders, port “A”. AdvantagesCOMBINABLE WITH SERIES 20 MANUAL VALVE for increased. The valve. It also permits shift. The VL is a manual control valve that is capable of processing single and double acting systems. The VR, on the other hand, is a regulating. Thank-you for your help. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. These valves are also listed with Sun's full line of Directional Cartridges. Sun's standard solutions are road tested and ready. You agree to our use of cookies by closing this message box or continuing to use our site. To find out more, see our Privacy Policy. Click OK to extend your time for an additional 0 minutes.By continuing to use the site, or by staying here, you agree to our use of cookies in line with our Knob and lever actuators are available with detents. All other parts hardened steel. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.http://xn--flrdochform-m8a.se/userfiles/3g3mx2-a4015-manual.xml To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. These valves are capable of flows up to 23 lpm (6 gpm) and pressures as high as 240 bar (3500 psi). Parker’s 3-way manual rotary spool valves operate throughout a 90 degree rotation with a closed center condition at 45 degrees. These valves are available with detented positions and are ideal for single direction applications, such as uni-directional motors or single acting circuits on a variety of machinery within the construction, material handling, or industrial markets. To view this site, you must enable JavaScript or upgrade to a JavaScript-capable browser.What is a Hydraulic Cylinder. Valves are used to manipulate the flow of hydraulic fluid within a hydraulic circuit and are activated either mechanically or electronically. Directional Control Valves are the most commonly used valve in a hydraulic system. Control valves direct the flow of hydraulic fluid from the pump to the actuators or other sections of the hydraulic circuit. Control valves are returned to their neutral state with a spring or held in each position with a detent mechanism. These valves are generally used to control the direction of a hydraulic motor or cylinder; they can also perform other functions in a circuit. A 2-way valve stops flow or allows flow. A water faucet is a good example of a 2-way valve. A water faucet allows flow or stops flow by manual control. This requires a 3-way valve. A 3-way valve allows fluid flow to an actuator in one position and exhausts the fluid from it in the other position. Some 3-way valves have a third position that blocks flow at all ports. A 4-way valve pressurizes and exhausts two ports interdependently.http://www.drupalitalia.org/node/66060 A 3-position, 4-way valve stops an actuator or allows it to float. The 4-way function is a common type of directional control valve for both air and hydraulic circuits. A 3-position, 4-way valve is more common in hydraulic circuits. A 5-way valve performs the same function as a 4-way valve. Because oil must return to tank, it is convenient to connect the dual tank ports to a single return port. For air valves, atmosphere is the tank, so exhaust piping is usually unimportant. Using two exhaust ports makes the valve smaller and less expensive. As will be explained later, dual exhausts used for speed-control mufflers or as dual-pressure inlets make this configuration versatile. Following are schematic symbols for commonly used directional control valves. The at-rest box or the normal condition is the one with the flow lines going to and from it. In Figure 8-1, the active box shows blocked ports, or a closed condition, while the upper box shows a flow path. When an operator shifts the valve, it is the same as sliding the upper box down to take the place of the lower box. In the shifted condition there is flow from inlet to outlet. Releasing the palm button in Figure 8-1 allows the valve spring to return to the normal stop flow condition. A 2-way valve makes a blow-off device or runs a fluid motor in one direction. By itself, a 2-way valve cannot cycle even a single acting cylinder. Figure 8-3 shows a solenoid pilot operator using solenoid-controlled pressure from the inlet port to move the working directional spool. Figure 8-4 shows a cam-operated valve. A moving machine member usually operates this type valve. These ports are: inlet, outlet, and exhaust (or tank ). A 3-way valve not only supplies fluid to an actuator, but allows fluid to return from it as well. Figures 8-5 through 8-10 show schematic symbols for 3-way directional control valves. Figure 8-6 depicts an all-ports-blocked, 3-way, 3-position valve.ATLANTICHURRICANE.COM/images/3-speed-synchromesh-manual-with-overdrive-unit.pdf A valve of this type connected to a single-acting, weight- or spring-returned cylinder could extend, retract, or stop at any place in the stroke. Another flow condition is the diverter valve shown in Figure 8-10. A diverter valve sends fluid to either of two paths. They range from the simple, two-position, single, direct solenoid, spring-return valve shown in Figure 8-11, to the more complex three-position, double solenoid, pilot-operated, spring-centered, external-pilot supply, external drain valve shown in Figure 8-15. Lines to the boxes show flow to and from the valve, while lines with arrows in the boxes show direction of flow. The number of boxes tells how many positions the valve has. This valve has a third position but there is no operator for it. Use this spring-centered, single solenoid valve in control circuits for special functions. In the past, to get this configuration, you only had to wire one solenoid of a double-solenoid, three-position valve. Figure 8-13 shows another unusual 4-way configuration. This valve shifts from an actuator moving flow path to center condition for certain special circuits. Most spool-type air valves come in a 5-way configuration. Because air usually exhausts to atmosphere, the extra exhaust port is no problem. Many valves use the two exhaust ports for speed control mufflers. Mufflers not only make the exhaust quieter, but throttle the exhaust, which in turn controls cylinder speed in a meter-out circuit. Also use dual inlet piping to make an air cylinder operate quickly and smoothly. (See Figures 8-48 through 8-55.) Most air cylinders stroke from one extreme to the other. A two position, single solenoid, spring return valve is sufficient for this operation. About 90 of air circuits use this type of valve. To stop an air cylinder in mid-stroke, use the 3-position valve shown in Figures 8-19 through 8-21. When the cylinder moves slowly, a repeatable mid stroke position of plus or minus an inch might be possible. The problem is, if the load on the cylinder changes or there is any slight leak in the piping or seals, it will not hold position once it stops. One use is the blow-off function shown in Figure 8-22. A 2-way valve in Figure 8-23 operates a one-direction motor with an open exhaust in the motor housing.Figure 8-25 shows a weight-returned, single-acting cylinder powered by a 2-way in the at rest condition. At first sight it looks as if this circuit might work. Shifting the 2-way valve, or extending, sends fluid to the cylinder cap end and it extends. The problem comes when the 2-way returns to normal at the end of cycle. Instead of the cylinder retracting after the solenoid de-energizes, it stays in the extended position. The cylinder would only return if the valve, cylinder seals, or pipe connections leak. One (NO) and one (NC) 2-way directional valve piped to the cap end cylinder port allows fluid to enter and exhaust from it. Actuating both operators simultaneously extends the cylinder. According to valve size and inlet air flow, the cylinder might not extend if just energizing the (NC) valve. If the cylinder extends with only one valve actuated, it would be slow and waste a lot of air. Figure 8-27 shows four 2-way valves piped to operate a double-acting cylinder. A pair of 2-way valves at each cylinder port gives a power stroke in both directions. Energize and de-energize all four valves simultaneously to cycle the cylinder and keep from wasting fluid. However, in the past few years, poppet type slip-in cartridge valves have been operating large bore hydraulic cylinders this way. See chapter four on Cartridge Valves for the advantages of these valves in high flow circuits. Using 3-way valves Figure 8-28 shows a 3-way valve, used to select Pr. 1 or Pr. 2. Use a spool type directional control valve in this type of circuit. Spool valves normally take pressure at any port without malfunction. Poppet design valves normally take pressure at the inlet port only. Most solenoid pilot-operated valves take air from the normal inlet port to operate the pilot section. If both inlet pressures are too low to operate the valve, plumb an external pilot supply from the main air system. Use a spool type valve here also. Poppet valves usually only take pressure at one port. This particular example is (NC). Contact with a machine member opens it. Except for bleeder type control circuits, a limit valve requires at least a 3-way function. In normal condition, fluid in the control circuit exhausts through the exhaust port. Energizing the solenoid, or extending, allows flow to move to the cylinder port and it extends. Deenergizing the solenoid or retracting, lets the valve shift to home position, and the cylinder retracts from outside forces. With a 3-way directional valve at both ports, both extend and retract strokes of a double-acting cylinder have force. Piping between the valve and cylinder ports wastes air. Every time a cylinder cycles, the lines to both ports fill and exhaust. The longer the valve-to-cylinder lines are, the greater the air waste. Mounting air valves directly to the cylinder ports minimizes air waste. The higher cycle rate results in greater savings. As discussed before, reducing air pressure at the cylinder uses less compressor horsepower. Usually, force required to return a cylinder is minimal, so lower pressure at the rod port saves energy. This saves piping time and the cost of flow control valves. It is possible to inch an air circuit if accuracy and repeatability are not important.Faster travel speeds give less control. To duplicate the 2-way function, block the exhaust port of the 3-way valve. Blocking the exhaust of a 3-way is usually not necessary for most 2-way applications. Using 3-way valves in place of 2-way valves reduces inventory cost and saves time. Using directional controls in ways other than normal is a common practice. Make sure the valve is capable of pressure in all ports before applying it to some of these circuits. If the valve is solenoid pilot-operated, where does pilot supply come from. Also check with the manufacturer if there is any doubt about the valve’s performance in an unusual application. Connect pump flow to the normal inlet port and its outlet port, then connect the other outlet port to the normal tank port and on to the system. In the at-rest condition there is no flow through the valve. A valve rated at 10 gpm is now good for 20 gpm with little or no increase in pressure drop. Make sure the valve is capable of backpressure at the tank port. Also, a lot of 2-way hydraulic valves only stop flow in one direction, so they are useless in a bi-directional flow line. Read Chapter 17 for a full explanation of this regeneration circuit. Figure 8-36 shows how to pressurize both ends of the cylinder when a 4-way valve centers. When a cylinder retracts to pick up another part, it often has to go too far to make sure it is behind the part. Low backpressure from the check valve makes the cylinder creep forward at low power so the cylinder is in contact with a part before the next cycle starts. A double-acting cylinder only needs one 4-way directional valve to extend and retract it. The three sequences show a 4-way valve in action. Add flow controls or a counterbalance valve to complete the circuit when there is weight on the rod. Note the port hookup is A to cap and B to rod. Maintenance persons always know which manual override to push during trouble shooting or setup. Valve center conditions perform different functions in relation to the actuator and pump. This reduces heat build up and allows opposing forces to move the cylinder without building backpressure. Most hydraulic valves are a metal-to-metal fit spool design, so do not depend on the cylinder setting dead still with a tandem center spool. If there are outside forces on the cylinder, it will creep when the valve centers. If the cylinder needs to float while blocking pump flow, use the center condition shown in Figure 8-40. The first four account for about 90 of all 3-position hydraulic valves in use. The open center condition unloads the pump and allows the actuator to coast to a stop or float. In the crossover or transition condition it causes very little shock. Fixed volume pumps use this center condition. The all-ports-blocked center condition valve of Figure 8-42 appears to block the cylinder ports. In actual use, leakage oil across the spool lands pressurizes A and B ports, possibly causing a single rod cylinder to extend. This is not a good choice for stopping and holding a cylinder as the symbol seems to indicate. To positively stop a cylinder, use a valve with the cylinder ports hooked to tank, and pilot-operated check valves in the cylinder line or lines. (See the section on “Check Valves as Directional Valves.”) Pump output is available for other valves and actuators with this center condition. It also works well for pilot-operated check valve locking circuits or with counterbalance valves. This is the normal center condition for the solenoid valve on a solenoid pilot-operated, spring-centered directional valve. A tandem center valve lets the pump unload while blocking the cylinder ports. The cylinder sits still unless there is an outside force trying to move it. Any metal-to-metal fit spool valve never fully blocks flow. With external forces working on the cylinder, it may slowly creep with the valve centered. This is another common center condition for fixed volume pumps. Connecting pressure oil to both cylinder ports and to each other regenerates it forward when the valve centers. This valve is the pilot operator for hydraulically centered directional valves or normally closed slip in cartridge valves. However, the metal-to-metal fit spool will not lock the cylinder when there are external forces. In some actuator applications it is important to know what the valve port flow conditions are as it shifts. As shown in these figures, dashed lined boxes show crossover condition. Normally discussions about crossover conditions cover “open” or “closed” types; in reality, the crossover condition may be a combination of these and may be different on either side of center. Open crossover stops shock while the spool shifts, while a closed crossover reduces actuator override travel. If the crossover condition is important to the circuit or machine function, show it on the schematic drawing. On most schematics, the simplified symbol is sufficient. The solenoid slash and energy triangle in the operator box show the valve has a solenoid operated valve piloting a pilot-operated valve. The boxes show the function of the main or working spool that controls the actuator. On valves with other hardware added (here, pilot chokes and stroke limiters), it is better to show the complete symbol. Both symbols in Figure 8-49 represent the same valve. The complete symbol gives more information about the valve function and helps with troubleshooting and valve replacement. Internal pilot supply (X) and external drain (Y). The 5-way selector valve and shuttle valve in Figure 8-50 works where a 3-way selector may not. The 3-way selector does fine when going from low to high pressure, but if there is no air usage to allow expansion, it is almost impossible to go from high to low pressure. After the air exhausts to the lower pressure, PR.1, the shuttle shifts and low pressure holds in the system. Either valve moves the cylinder to its opposite position when activated. Normally, input air goes to the center port of the side with three ports.The exhaust ports often have speed control mufflers to reduce noise and control the amount of exhaust flow. Speed control mufflers give individual meter-out speed control in each direction of travel. Use a spool type valve for this hookup, since it takes pressure at any port without malfunction. Putting low pressure on the rod side of the cylinder uses less compressor air without affecting the operation. This air savings results in lower operating cost and leaves more air to run other actuators. Install flow controls in the lines to the cylinder ports for individual speed control. On the circuit in Figure 8-53 a pilot line from system pressure goes directly to the pilot valve. System pressure goes into the external pilot supply port and a plug shuts off the internal pilot port. Changing the pilot line in the field with assistance from the supplier’s catalog is quite easy. Figures 8-54 to 8-61 show another reason for using dual pressure inlets. They depict air cylinder movement with conventional hookup. The cylinder pauses before raising and drops rapidly when starting to retract. Figure 8-54 shows a conventional 5-way valve hook up on a cylinder raising a 600-lb load. This figure shows weight, cap and head end areas, and pressures at both cylinder ports. The weight-to-cylinder force ratio and the rate of cylinder travel speed control the length of pause. The heavier the weight and the slower the cylinder speed, the longer the pause. The delay could be three to four seconds in extreme cases. At the moment the valve shifts to extend the cylinder, down forces are up to 1240-lb while up force is only 800 lb. As long as down forces exceed up force, the cylinder will not move. The slower the air exhausts, the longer it takes to get enough differential pressure across the cylinder piston to move it. The speed of exhausting air controls how fast the cylinder moves once it starts. It moves up smoothly and steadily as long as the load remains constant. Figure 8-57 shows the cylinder at rest at the top. Up force is 800 lb from air pressure on the cap end, and down force is 600 lb from the weight. Now the load drops rapidly until air pressure in the cap compresses to approximately 120 psi. It takes about 120 psi on the 10-in.2 area to slow the cylinder’s rapid retraction. This sets a pressure differential across the piston before the valve shifts. The cylinder starts to move almost immediately and continues moving smoothly to the end. With the head end regulator set at 15 psi, down force from air pressure and the load is almost offset by up force. The load lowers smoothly and safely without lunging or bouncing, as fast as cap end air exhausts. In figure 8-59 to 8-61, the cylinder strokes smoothly and quickly in both directions with dual-pressure valve. These are two of the three actions a directional control valve can perform. Figure 8-62 shows the symbol for a plain check valve. Heat exchangers, filters, and low-pressure transfer pumps often need a low-pressure bypass or relief valve. A check valve with a 25-125 psi spring makes an inexpensive, non-adjustable, flow path for excess fluid. It protects low-pressure devices in case of through flow blockage. Pilot operated directional valves commonly use a check valve in the tank or pump line to maintain at least 50-75 psi pilot pressure during pump unload. Some manufacturers make a check valve with an adjustable spring, for pressures up to 200 psi or more. The symbol in Figure 8-64 shows how to represent this in a symbol. A common use for a drilled check valve is as a fixed, tamper proof, flow control valve. Fluid free flows in one direction, but has controlled flow in the opposite direction. The only way to change flow is to change the orifice size. This flow control valve is not pressure compensated. Hi-L pump circuits, reverse free flow bypass for flow controls, sequence valves or counterbalance valves, and multi-pump isolation, to name a few. Figure 8-65 shows some other applications for check valves. When the tank is higher than the pump or directional valves, always install some means to block flow lines for maintenance. If the valves are not blocked, the tank must be drained when changing a hydraulic component. Shut-off valves are the only option for lines that flow out of the tank to a pump or other fluid using device. To avoid running the pump dry, its shutoff should have a limit switch indicating full open before the electrical control circuit will allow the pump to start. All return lines though, can have a check valve piped as shown in Figure 8-65. A check valve with a low-pressure spring, called an tank isolation check valve, on each return line allows free flow to tank, while blocking flow out of it. A check valve in the tank lines makes shut off automatic and eliminates chances of blowing a filter or wrecking a valve at startup. The backpressure check valve in the pump line maintains a minimum pilot pressure while the pump unloads. Here it is in the line feeding the directional valves, other times it is in the tank line. In either case it provides pilot pressure to shift the directional valves when a new cycle starts. An external force can pull against the trapped oil in the cylinder and cause damage or failure without relief protection. When outside forces move the cylinder, fluid from the rod end goes to the cap end, but is not enough to fill it. If a void in the cap of the cylinder is no problem then an anti-cavitation check valve is unnecessary. However, this void can cause erratic action when the cylinder cycles again, so install an anti-cavitation check valve. The anti-cavitation check valve has a very low-pressure spring, which requires 1-3 psi to open, so it allows tank oil to fill any vacuum void that might form. The anti-cavitation check valve has no effect during any other part of the cycle. The following images show symbols of pilot-operated check valves that allow reverse flow. Figure 8-66 shows the symbol for a standard pilot to open check valve. Figure 8-67 shows a pilot-operated check with a decompression feature. The symbol in Figure 8-68 shows a pilot-operated check valve with an external drain for the pilot piston. Each of these pilot-operated check valves allow reverse flow, but two of them have added features to overcome certain circuit conditions. Metal-to-metal fit spool valves will not hold a cylinder for any length of time. As shown in Figure 8-69, a blocked center valve can actually cause a cylinder to creep forward. Vertically mounted cylinders with down acting loads always creep when using a metal-to-metal fit spool valve. Hydraulic motors always have internal leakage so the circuits shown here will not hold them stationary. Figures 8-70, 8-71, and 8-72 show a typical pilot-operated check valve circuit that prevents cylinder creep. When using an on-off type solenoid valve, a fast moving cylinder stops abruptly when the directional valve centers. Use a proportional valve with ramp timers to decelerate the actuator and eliminate shock damage. This center condition allows pilot pressure to drop and the pilot-operated check valves to close. Using a directional valve with blocked A and B ports in center condition, may keep the pilot-operated check valves open and allow cylinder creep. If it is only necessary to keep the cylinder from moving in one direction, one pilot-operated check valve will suffice. Pump flow to the cylinder cap end builds pressure in the pilot line to the rod end of the pilot-operated check valve, causing it to fully open. The pilot-operated check valve in the line to the cap end opens by pump flow like any check valve. Energizing and holding a directional valve solenoid causes the cylinder to move. Pilot operated check valves positively lock the cylinder but are invisible to the electric control circuit. Pump flow to the cylinder rod end builds pressure in the pilot line to the cap end of the pilot-operated check valve, causing it to fully open. The pilot-operated check valve in the line to the rod end opens by pump flow like any check valve. Energizing and holding a directional valve solenoid causes the cylinder to move. In the example cited, a 15,000-lb platen pulling against a 26.51 square inch rod end area gives a 566 psi load-induced pressure. This load-induced pressure holds against the poppet in the pilot-operated check valve, forcing it closed. The pilot piston must have sufficient pressure to open the poppet with 566 psi pushing against it. The pilot piston on most pilot-operated check valves has an area that is three to four times that of the poppet. This means it will take approximately 141-188 psi at the cap end cylinder port to open the poppet for reverse flow. At about 150 psi the poppet in the pilot-operated check valve opens and allows oil from the cylinder rod end a free flow path to tank. The cylinder immediately runs away, pressure in cylinder cap port drops, the pilot-operated check valve closes fast and hard, and the cylinder stops abruptly. When the pilot-operated check valve closes, pressure at the cap end cylinder port again builds to 150 psi, opening the check valve, and the process starts again. A cylinder with these conditions falls and stops all the way to the work unless it meets enough resistance to keep it from running away. However, the restriction could cause fluid heating and slow cycling, and would need frequent adjustment to maintain optimum control. With the flow control after the pilot-operated check valve, use one with an external drain. When there is much backpressure on the outlet of a pilot-operated check valve, it is best to use one with an external drain. See chapter five for the different types of counterbalance circuits.