bosch security solution 16 manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:bosch security solution 16 manual.pdf
Size: 2608 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 4 May 2019, 18:50 PM
Rating: 4.6/5 from 673 votes.
Status: AVAILABLE
Last checked: 17 Minutes ago!
In order to read or download bosch security solution 16 manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
bosch security solution 16 manualI would like to thank anyone Without your help Any comments on this site please click below to email me. If you cant find the BOSCH Installation Manual Click below if you have BOSCH manuals that my site needs and i will add them straight away. Zones are identified by the area they monitor, such as a front door, bedroom window or hallway.Fire alarm in memory (Turn the area All On and Off to Clear).Key Pressing any key on the keypad sounds one Press short beep, indicating that the key press is Tone accepted.Only tokens that have been assigned to the same area(s) as the Master user cn be identified.Smoke Sensor Reset MENU 3-0-5 To turn OFF, Press OFF. This menu allows you to reset smoke sensors.The keypad will display a list of areas that are available to walk test zones.Press OK or MENU The third line of the keypad display scrolls between all current system trouble events.You should contact your security company. Service Mode The security installer has entered service mode. Phone In Use The system is using the phone line. Countless hours are wasted just staring at it when all you need is the right instruction manual. Thanks AussieGroupSecurity.com.au 1300 795 446 By taking the time to understand your company, we can tailor a security solution that delivers your ongoing needs and meets the expectations of your company. Empowered to respond quickly, our team commits to a solution and follow-through. Pay for business insurance online What's your policy number. What's the postcode for this policy. Pay online Need to update your policy. Log in to your Self Service Centre account to check your policy coverage before you renew. LOG IN TO SELF SERVICE CENTRE Other ways to pay Request a quote Call 132 553 Alarm user manuals Lost your user manual or wanting to know more. Download our alarm system user manuals here. We can also discuss your upgrade options to help ensure you're covered with the level of security you require. Get your insurance quotes today.http://www.italiangreyhound.pl/img1/userfiles/bosch-maxx-5-manual-english.xml
- Tags:
- bosch alarm solution 16 manual, bosch alarm solution 16 plus manual, bosch alarm system solution 16 manual, bosch solution 16 security system manual, bosch security solution 16 manual, bosch security solution 16 manual download, bosch security solution 16 manual pdf, bosch security solution 16 manual free, bosch security solution 16 manual online.
SGIC is part of the Insurance Australia Group. Business address 122 Grenfell St, Adelaide SA. Insurance (except Travel Insurance) issued by Insurance Australia Limited ABN 11 000 016 722 trading as SGIC. When making decisions about our insurance policies you should consider the applicable Product Disclosure Statement available from SGIC. The Loyalty Discount and No Claim Bonus replaces our previous discount structure, and applies to new eligible policies which commence on or after 8 September 2013, and renewing eligible policies which commence on or after 21 October 2013. Get your insurance quotes today. SGIC is part of the Insurance Australia Group. Business address 122 Grenfell St, Adelaide SA. Insurance (except Travel Insurance) issued by Insurance Australia Limited ABN 11 000 016 722 trading as SGIC. When making decisions about our insurance policies you should consider the applicable Product Disclosure Statement available from SGIC. The Loyalty Discount and No Claim Bonus replaces our previous discount structure, and applies to new eligible policies which commence on or after 8 September 2013, and renewing eligible policies which commence on or after 21 October 2013. They are easy to install, easy to program as its all from the keypad and text based not led based. Its even easier if you have the solution software and link cable. Programming it can be done before you even get to the job.Most of the time a professional will do this for you. h. Read more owever if your tech savvy you could probably do it yourself.Solution 6000 is the successor. Nbn integration currently not possible. GSM module attached to the 6000 series is the only current way to do sms reporting. Like Report Similar opinion. Write a review on ProductReview.com.au ! JessicaJ100 AU Its a very easy to use system and has a English display keypad which is a nice touch - you don't have to look anything up to see what it wants. Warns you if you have left any doors or sensors open on your way out.http://esllearningbydesign.com/app/webroot/files/bosch-maxx-4-silence-manual.xml Great feature is the SMS which tells you if the alarm has gone off, and also tells you where it has gone off. We have had no trouble from it or the Quad sensors we bought with it. The guys at cheat alarm parts helped us with some of the programming, but it was all straight forward. Would recomend Bosch products. Very happy. Easy to use. SMS's when alarm goes off. 1 like Share More Similar opinion. I have Bosch Solution 16 plus as security alarm where zones enable so notification can send messages to my mobile if intruter step on the zones. ( via Landline ) I heard that is an add-on sim module, can this module do the same as above.What is the name of the module. If that is one. As I am planning to cut my landline as I hardly use the landline to made calls, basically my land line is for my present ADSL. Like Share More 2 answers Chris 2 months ago Hi, I have the same system and was connected to nbn last week. Was told i needed to replace the main board to a 6000 wireless unit, the control panel and pay ifob membership etc. I have temporarily run a phone line cable from the telco output on the 16plus mother board to the phone input on my internet provider's modem (not the nbn device) and the system immediately sent an sms to my mobile saying comms restored. Internet working fine with no problem streaming. Like Report Chris 2 months ago Oh, should mention i left the line filter from my old adsl connection in the line from the bosch to the modem Like Report Caroline C asked 5 months ago We have a Bosch 16 plus alarm system. We are trying to install NBN but we are unable to connect properly as we are unable to turn system off. What should we do?? Like Share More No answers Sarah asked 1 year ago Hi the old owner is getting sms messages from our Bosch Solution 16 alarm. I follow the instructions to clear their mobile number but it says there are no numbers listed. Register now and take advantage of ProductReview's Brand Management Platform.https://www.becompta.be/emploi/4-laning-manual Manage this listing ProductReview.com.au has affiliate partnerships. Your Home Security Solution You’ve worked hard for the things that you own. Your home is your sanctuary.If an intruder breaks into your home, the loss you feel is not just about the items destroyed or stolen - they can be easily replaced. What you lose is the peace of mind and that sense of security that your home once provided. Finding the right security system to protect your home andfamily doesn’t need to be a complex and time consuming task. The Solution 16plus from Bosch Security Systems offers you the perfect solution. We’ve created a security system that has all the technology it needs to identify intruders to your home, without being hard to use. Solution 16plus helps you protect the things you love, providing you with reliable home security at your fingertips. Reliability You Can Trust The Solution range of security systems have been market leaders for over twenty years. Designed and manufactured in Australia, they represent thousands of man hours of development at Bosch, using an on-going process of customer feedback that is constantly engineered into our security systems every year.The result is a tried, tested and continually enhanced security system that is built to provide you with years of trouble-free performance.Fingertip Control The part of the security system that you use every dayis the code pad. Not only is it the way you control thesecurity system, but it also tells you what’s happeningwith your system. That’s where most security systems fail!Flashing lights and numbers mean nothing to you whenthe alarm is sounding and you’re trying figure out what theIn fact, more than90 of false alarms from security systems are caused byuser error. The Solution 16plus code pad eliminates many of thesecauses of false alarms because it’s designed to makeusing your security system extremely simple.http://www.fernandosued.com/images/bosch-security-panel-manual.pdf Just likean ATM, the code pad screen will prompt and guideyou with words, to make sure that you’re pressing theright buttons for the setting that you want. With onetouch of your code pad you can turn your securitysystem on. It’s that easy! At a glance, the code padscreen will also tell you with words and symbols what thecurrent system status is, and when the screen is not being used, the security system will also show you the date andtime of day. This extremely easy to use code pad is also designed tophysically fit in with any home decor. Choose the whitecode pad to blend with your home’s neutral tones, or the modern black version to make a statement. Intruders violate the sense of security your home should provide. Bosch, the brand you know and trust, offers you a Solution that’s reliable, uncomplicated, and affordable. Providing Peace of Mind The Solution 16plus can support up to 16 security devices, including internal motion sensors and door or window contacts. When an intruder is detected, the Solution 16plus can sound sirens, alert your monitoring centre, and activate lights, providing security you can rely on 24 hours a day. Not only will the Solution 16plus look after your home, it can provide you the peace of mind knowing that your children are safe. Your Solution 16plus can send a text message to your mobile phone to let you know that your children have arrived home safe from school and have turned off your alarm system. The Freedom of Choice Some people are good with numbers. Some people will forget them. What good is a PIN number if you can’t remember it. At Bosch, we understand that your security system needs to fit in with your way of life, so we’ve given you a choice when it comes to turning your security system ON (Arming) and OFF (Disarming). Rather than having to remember a PIN number, Solution 16plus code pads can allow you to simply present a key ring sized token or card to the face of the code pad which will turn your security system ON or OFF. This option is particularly useful for the elderly and children. You can also have your Solution 16plus security system programmed to use a small wireless remote control that fits onto your key ring. Working like your car remote, it lets you turn the security system ON or OFF as you leave or enter your home by pressing one simple button. It makes life simpler when you’re hands are full with shopping bags. The wireless remote control can also act as a portable panic button, and can even be programmed to switch on lights or open garage doors and automatic gates. Simple Short Cut Keys Like your PC, a security system can be a complicated machine to run. What you really need are some short cut keys to get you where you want to go quickly and easily. At Bosch, we’ve thought about the ways in which most people use their security system, and provided you with 2 buttons on your code pad that will make your system so much easier to use. The button called AWAY lets you to turn ON (Arm) both the internal motion sensors and protected doors and windows when you are leaving your home. All security devices are on alert for an intruder. The button called STAY lets you turn ON (Arm) the security system to protect the perimeter devices while allowing you to move around inside, without causing annoying false alarms. You can also use STAY mode to have one part of your home protected (like downstairs) while you are asleep in another (upstairs or the bedrooms). If an intruder enters through a protected door or window, an alarm will be immediately activated. In this way, Solution 16plus protects your home and family whether you are at home or away. Technology that’s Cost Effective The Solution 16plus is a state of the art security system that won’t break the bank. Bosch offers you all the technology you need to protect your home and family at an affordable price. Because each home is different, your alarm installer will put together a cost effective security solution that best suits your family and the layout of your home. A comprehensive range of Bosch accessories to compliment your security system are available, like remote controls and cards or tags. For apartments or homes where it’s difficult to run wires, a range of wireless sensors can be quickly and easily fitted to your system to ensure your home is protected.Dual Microwave and PIR technologies with pattern recognition technology, means this detector is perfect for the home, office, or garage. CP100 Slim Line Graphic Text Codepad for system interaction. For a complete range of available accessories, please ask your security representative.Bosch Security Systems proudly offers a wide range of intrusion, CCTV, access control, social alarm, fire management and communication systems and components to help you find the solution for any application. We are the global supplier of choice for innovative technology backed by the highest level of service and support. When you need solutions you can rely on, choose Bosch., or 3.65 k? EOL Resistor Option. Refer to Figure 13. Use any number of normally-closed (NC)Use any number of normally-openFigure 13: Single 1 k?, 2.2 k?, or 3.65 k? EOL Resistor OptionRefer to Figure 14. Place up to five normally-closed contacts inFigure 14: 2.2 k? Alarm Resistor and Tamper OptionNC tamper switch (optional)A cover tamper switch transmits a tamper signal when the cover isAn LED provides status for RFSS and Discovery Modes. Table 12: Recessed DW Contact Specifications and Required Tools. Maximum Distance Between. Reed Switch and Magnet. Drill Tools. Circuit Board Removal. One CR2 lithium battery, 3 VDC. Needle nose pliers are recommended. Mounting the wLSN Recessed DW Contact in a metal doorA cover-and-wall tamper switch transmits a tamper signal whenAn LED provides status for RFSS, and Discovery Modes. Table 13: wLSN Mini DW Contact Specifications. The magnet can be placed on either side ofFigure 16: Mini Door-Window Contact Tamper SwitchThe wLSN Inertia Detector is a vibration detector combined with aA cover-and-wall tamper switch transmits a tamper signal whenAn LED provides status for Test, RFSS, and Discovery Modes. Table 14: Inertia Detector Specifications. Between DetectorThe magnet can be placed on either side of theThe arrow, embossed on the bodyRefer to Figure 17. Figure 17: Sensor AdjustmentRoute the wiring from the sensor element so it does notRefer to Figure 18. Figure 18: Wiring RouteAll sensitivity settings are programmed at the control panel (referGross Attack. Minor Attack. Gross Attack is always enabled. The Minor Attack setting is veryGross Attack Sensitivity. The Gross Attack setting measures vibration activity for a specifiedLow (default). Low to Medium. Medium to high. High. The settings determine the length of time vibration activity isMinor Attack. Programming at the control panel determines how many repetitiveBy default, Minor Attack is disabled. If enabled, there are twoFour Taps. Eight Taps. When a tap occurs, a 90-sec timer starts. If the tap count exceedsA single tap such as a branch in the wind lightly brushing aThe unit is automatically in Test mode for the first 10 minutes afterThe green LED flashes:Test mode. Twice to indicate a Minor Attack activation. Three times to indicate a Gross Attack activationThe wLSN Key Fob is a two-way personal transceiver carried by theFive buttons: Two buttons are for arming and disarming. TwoTo operate the intendedTwo LEDs: One LED indicates status and the other is suitableFigure 19: Key Fob Buttons and LEDsStatus LED. Disarm button. Arm button. Programmable buttonsGasketsInterchangeable; for multiple users, different colorsKey Fob Buttons. Refer to your control panel’s documentation to program thePressing any button causes the status LED to flash alternately redThis indicates that commands werePressing and holding both the arm and disarm buttons togetherFor specific information regarding the various LED states, refer toThe wLSN Relay Module allows the control panel to controlThis module also providesAuxiliary power input terminals are also provided to supplementA cover-and-wall tamper switch transmits a tamper signal whenAn LED provides status for RFSS and Discovery Modes. Table 16: Relay Module Specifications. Auxiliary Power. Input. Terminal Blocks. Relay OutputFour AA batteries, 1.5 V alkalineCompatible with any 12 VDC nominal power supply. External power source, 12 VDCInput, supervised sensor loopNO, C, NC (output) Relay output for control ofThe external power option is intended to be used as aThe wLSN Indoor Siren provides auxiliary power input terminalsA cover-and-wall tamper switch transmits a tamper signal whenAn LED provides status for RFSS and Discovery Modes. Table 17: Siren Specifications. SounderFour AA batteries, 1.5 V alkalineCompatible with any 12 VDC nominal power supply. External power source,The external power option is intended to be used as aUnder normal conditions, the red LED flashes once every 8 secRefer to TableA self-diagnostic feature monitors detector sensitivity andA cover tamper switch transmits a tamper signal when the cover isThe optical chamber is removable for easy maintenance. Table 18: Smoke Detector Specifications. Fixed Temperature. Sensor. Rate-of-Rise Sensor. Photoelectric Beam. Obscuration Sensitivity. Drift Compensation. Adjustment. Average Alarm Current. Sounder. Two lithium batteries; 3 VDCReplace batteries when the LED stops flashing and the sounderThe low battery trouble chirps can be silenced for 24 hours by. Refer to Figure 20 on page 46 forTo avoid a fire department dispatch, contact the centralTest smoke detectors annually using an approved aerosol smokeFollow the instructions on the can. The LED should remain on while the detector provides aTest mode is seen by the control panel as a test. It doesThe detector includes a Sensitivity Level Test mode forRefer to Figure 20 on page 46.Table 19: Smoke Detector Sensitivity Conditions. FlashesAction Recommended. Self-diagnostics failure. Return device for service or replacement. Device is becoming insensitive. Clean the detector and re-test. IfDetector is within normal sensitivity range. Device is becoming too sensitive. Confirm that the smokeClean the sensor and re-test.If smoke is still present afterOn. Status. Flashes every 8 sec under normal operation. Detects smoke, sending an alarm. Malfunction, replace the batteries, clean the detector, orClean the detector cover with a dry or damp cloth as needed toClean the detector interior at leastTo clean the detector:Figure 21: Remove the Detector CapFigure 22: Remove the ChamberRefer to Section 6.11.3 Sensitivity Test on page 47.To default the Smoke Detector:Figure 23: Remove Smoke Detector from BaseFigure 24: Separate Housing Cover and BaseFigure 25: Transmitter PCB and Jumper PinsDo not close the housing base. The detector is now defaulted.A cover-and-wall tamper switch transmits a tamper signal whenTable 21: Glass Break Detector Specifications. Accoustic. CapabilitiesType. Glass types andPlate. Minimum paneRangeTemperedWiredMaximum 7.6 m (25 ft). No minimum range. Figure 26: Glass Break Front LayoutAA batteries. Service door. Test Mode pads. Sensitivity DIP switches. Event LED. Alarm LED. LED enable switch (off position). Housing screw. RFSS Mode LED (remove housing screw and cover piece)Glass break detectors are intended only as a componentYou should always use aFor the best detector performance, select a mounting location thatAvoid mounting the detector:ENABLE switch (Item 8, Figure 26) in the direction the arrowAn orange flag protrudes from theFigure 27: Glass Break Sensitivity SwitchesSensitivity switchesTable 22. Table 22: Glass Break Sensitivity Settings. Sensitivity. Maximum. Medium. Low. LowestIf the green LED flashes, relocateTest the detector at least once each year. Test the detector withFigure 28: 13-332 Sound Sensor TesterEntering Test Mode. Place the detector in Test Mode. In Test Mode, the detector’s LEDTo enter the Test Mode locally:The Event LED (green) (Item 6, Figure 26 on page 53) flashesThe 13-332 Sound Sensor Tester produces extremelyTo enter the Test Mode remotely:The tester buzzes and the green LED on the detector flashes onceThe tester activates and starts an eight-sec armed period.Tester responds by producing a burst of glass break audio. If the detector receives both the flex and audio signals properly,If the red LED does not light, return to Section 3.0 RFSS Site. Evaluation on page 7 to reposition the detector. Exiting Test Mode. To exit the Test Mode locally:When the detector exits Test Mode, the green Event LEDIf the Event LEDTo exit the Test Mode remotely:The tester buzzes.The detector indicates a low battery condition in two ways. If the LEDs are enabled, both flash simultaneously every sec. A low battery status indication is sent to the control panel. The LED flashing and a low battery indication at the control panelEntering RFSS Mode. To enter RFSS Mode if the wall tamper tab is removed:Refer to Figure 29.Refer to Figure 29. The detector enters RFSS Mode. Figure 29: Wall and Cover Tamper SwitchesCover tamper switch (inside of detector)If the wall tamper tab is removed and you must return the defaultRefer to Figure 29 on page 59.The RFSS Mode LED turns on. Refer to Figure 26 on page 53 for the location of the RFSS. Mode LED.RFSS Mode LED turns on. The detector is now defaulted.Table 23: Icons and Symbols. Icon or Symbol. Meaning. Pet Friendly (appropriate weights below graphic)Point away from rotating machines. Point away from objects that rapidly change temperature. Do not mount in sunlight. Do not point toward window. Do not mount outside. Device has a wall or cover tamper. Not pet friendly when lookdown zone is enabled.PDF Version: 1.4. Linearized: No. XMP Toolkit: 3.1-702. Producer: Acrobat Distiller 7.0.5 (Windows). Create Date: 2007:12:03 13:46:46-05:00. Creator Tool: PScript5.dll Version 5.2.2. Modify Date: 2007:12:03 13:53:36-05:00. Metadata Date: 2007:12:03 13:53:36-05:00. Creator: bnt5fp. Document ID: uuid:6f4095c4-060d-4138-88d6-e1feefc00882. Instance ID: uuid:5bb830a5-329f-4f81-8118-9c43e7c66567. Page Count: 62. Author: bnt5fp. If a seat is not assigned to a participant, thatParticipants cannot use an NFC tag to identify themselves. A seat can be used without having to identify the participant, by assigning a dummyAt assigned seat (grey). If a seat is not assigned to a participant, thatParticipants must use an NFC tag to identify themselves at the assigned seat.The seat cannot be used until the assigned participant is identified at the seat. At any seat (grey). Participants can use an NFC tag at any seat to identify themselves. The seat cannot be used, until a participant has been identified at that seat. Participants overview. Trash can: Removes the selected participant. Name: The participants (editable) name. NFC?ID: The number of the Near Field Communication (NFC) tag of the participant. Seat: Selects the seat name, from the list, that the participant is assigned to. Configuration manualThe logged on user must have the access right: Prepare system.Click the Switch system on button to set the system in the “power on” mode. Press the microphone request button of a Wireless Device to switch it on. Note: The Wireless Devices have to be switched on individually. Click the Switch system off button to set the system in the “power off” mode. This willNote: If you try to switch on a Wireless Device, by pressing the microphone requestThe logged on user must have the access right: Configure or Prepare system. The following information is shown for each seat that is currently connected to the Wireless. Access Point. Note: If a seat is disconnected, the disconnect symbol is displayed to the left of the seat row,Seat: The seat name. Battery: Indicates the remaining power supply capacity, in hours, of the Wireless Device. Battery Pack. Note: After replacing a battery or powering up a Wireless Device, the number of batteryThis value will stabilizeCharges: Shows the number of times the Battery Pack battery is charged. On the toolbar, click the Devices tab. 2. Click Refresh (below the tree structure). Configuration Manager scans the network for devices and displays them with their current settings. This means that Configuration Manager automatically has access to the device when establishing a connection without the password protection having to be disabled each time. Special characters are not supported for the password and can prevent you from being able to access the program. 7.6 Replacing devices If devices must be replaced, most of the configuration for the new devices can be done automatically using the Replacement function. To replace devices: 1. On the toolbar, click the Preferences tab, expand Applications in the tree structure, click Configuration Manager, then click the Repository tab. 2. In the Database folder box, enter the location in which configuration data is to be backed up. 3. On the toolbar, click the My Devices tab, right-click the device, click Settings, then click Download. The device configuration settings are saved locally on your PC. 4. Replace the device. 5. In Configuration Manager, click the My Devices tab. If it is not possible to transfer all the data, the number of data packets not transferred is listed in the Failed column. Once the transfer is complete the device is rebooted so that the new settings take effect. When the Cancel button is replaced by the Close button, the procedure is complete. 12. Click Close. The Device Replacement Wizard dialog box is displayed again. 13. Click Finished to complete the procedure. These settings are relevant for Video Client. You can select any directory that is available in the network as the target location. Delete recordings that are no longer required. If a device is replaced by one of the same type, the configuration data can be transmitted straight to the new device. To download data for offline configuration: 1. On the File menu, click Work Offline. If any of the devices in the system do not support offline configuration, a message is displayed. Click OK to continue. 2. In the next dialog box, you can choose whether current configuration data of all devices in the system is to be saved to the local repository. Click Yes to update your locally saved device database. 3. The Download of Settings dialog box lists all devices for which configuration data is currently being transferred. 4. Click Start. If it is not possible to transfer all the data for individual devices, the number of data packets not transferred is listed in the Failed column. When the Cancel button is replaced by the Close button, the procedure is complete. 5. Click Close. If the configuration data is inconsistent for individual devices, you will receive a warning message. You can cancel the procedure at this stage and then continue to work online. If you ignore the warning, you will work offline. Offline now appears in the status bar: 6. Now use Configuration Manager to configure the devices offline. Any changes that you now make will only be saved locally on your computer. Configuration Manager always starts up in online mode. If Configuration Manager was closed while offline, on the next start you will receive a message if the configuration files in the repository differ from the current device settings. You can then choose whether to upload. You can also perform the transfer for an individual device, for example, to back up the configuration locally before a device is replaced. To back up configuration: 1. 2. On the toolbar, click the Devices or My Devices tab. Right-click the device, click Settings, then click Download. To uploading offline configuration data: 1. On the File menu, click Work Online. 2. To send the amended configuration data to specific devices, select these devices in the My Devices tab. 3. Right-click these devices, click Settings, then click Upload. The selected devices are listed in the Upload of Settings dialog box. 4.